The error is occurred and cannot change resolution of image when chaning resolution setting on frame grabber board based on resolution of camera.
It is possible to have some restriction for change resolution based on frame grabber manufacture or type of frame grabber board.
For example:
It is necessary to specify multiple of 48 for horizontal size (x size, width) when selecting 3TAP configuration.
It is necessary to specify multiple of 80 for horizontal size (x size, width) when selecting 10TAP configuration.
Please contact frame grabber board manufacture about restriction between selective TAP configuration and resolution.