{"id":11708,"date":"2025-09-04T14:44:49","date_gmt":"2025-09-04T05:44:49","guid":{"rendered":"https:\/\/sentech.co.jp\/faq\/faq-7765"},"modified":"2025-09-27T18:37:26","modified_gmt":"2025-09-27T09:37:26","slug":"faq-7765","status":"publish","type":"faq","link":"https:\/\/sentech.co.jp\/en\/faq\/faq-7765","title":{"rendered":"In StViewer, GigE Vision camera is displayed but the OK button cannot be selected, so I cannot use the camera."},"content":{"rendered":"\n<p>This occurs when the PC\u2019s network card (NIC) and the GigE Vision camera are not on the same network. Please check and adjust the IP address settings of both the NIC and the camera.<br\/>The NIC\u2019s IP address can be checked in the Device Selection screen under Interface Information.<br\/>The camera\u2019s IP address can be checked in the Device Selection screen under Device Information.<\/p>\n\n<p>How to set the IP address:<\/p>\n\n<ol class=\"wp-block-list\">\n<li>In the Device Selection screen, select the camera you want to use and click the Set IP Address button in the lower-left corner.<\/li>\n\n\n\n<li>In the Set IP Address screen, set the Device Configuration -&gt; IP Address and Subnet Mask to match the NIC Configuration -&gt; IP Address and Subnet Mask.<br\/>For the IP Address: use the same first three values as the NIC\u2019s IP Address, but set the last value (1\u2013254) different from the NIC\u2019s IP.<br\/>For the Subnet Mask: use the same value as the NIC\u2019s Subnet Mask.<br\/>Click OK to save.<\/li>\n\n\n\n<li>Return to the Device Selection screen and click OK to connect the camera.<\/li>\n<\/ol>\n\n<p>Example:<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>IP address information \/ Device<\/td><td>NIC Configration<\/td><td>Device Configration<\/td><\/tr><tr><td>IP Address<\/td><td>169.254.237.65<\/td><td>192.168.3.165<\/td><\/tr><tr><td>Subnet Mask<\/td><td>255.255.255.0<\/td><td>255.255.0.0<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ol class=\"wp-block-list\">\n<li>Open the Set IP Address screen.<\/li>\n\n\n\n<li>Set the Device Configuration IP Address to 169.254.237.50 and Subnet Mask to 255.255.255.0.<br\/>Click OK.<\/li>\n\n\n\n<li>Return to the Device Selection screen, and select OK again to connect the camera.<\/li>\n<\/ol>\n","protected":false},"featured_media":0,"template":"","faq_cate":[250,257],"class_list":["post-11708","faq","type-faq","status-publish","hentry","faq_cate-gige-vision","faq_cate-gige-vision-stviewer"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>In StViewer, GigE Vision camera is displayed but the OK button cannot be selected, so I cannot use the camera. | FAQ | OMRON SENTECH CO., LTD.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sentech.co.jp\/en\/faq\/faq-7765\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"In StViewer, GigE Vision camera is displayed but the OK button cannot be selected, so I cannot use the camera. | FAQ | OMRON SENTECH CO., LTD.\" \/>\n<meta property=\"og:description\" content=\"This occurs when the PC\u2019s network card (NIC) and the GigE Vision camera are not on the same network. Please check and adjust the IP address settings of both the NIC and the camera.The NIC\u2019s IP address can be checked in the Device Selection screen under Interface Information.The camera\u2019s IP address can be checked in [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sentech.co.jp\/en\/faq\/faq-7765\" \/>\n<meta property=\"og:site_name\" content=\"OMRON SENTECH CO., LTD.\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-27T09:37:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/sentech.co.jp\/wp-content\/uploads\/2025\/09\/ogp.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sentech.co.jp\/en\/faq\/faq-7765\",\"url\":\"https:\/\/sentech.co.jp\/en\/faq\/faq-7765\",\"name\":\"In StViewer, GigE Vision camera is displayed but the OK button cannot be selected, so I cannot use the camera. | \u3088\u304f\u3042\u308b\u3054\u8cea\u554f | OMRON SENTECH CO., LTD.\",\"isPartOf\":{\"@id\":\"https:\/\/sentech.co.jp\/en#website\"},\"datePublished\":\"2025-09-04T05:44:49+00:00\",\"dateModified\":\"2025-09-27T09:37:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/sentech.co.jp\/en\/faq\/faq-7765#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sentech.co.jp\/en\/faq\/faq-7765\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sentech.co.jp\/en\/faq\/faq-7765#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u30db\u30fc\u30e0\",\"item\":\"https:\/\/sentech.co.jp\/en\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3088\u304f\u3042\u308b\u8cea\u554f\",\"item\":\"https:\/\/sentech.co.jp\/en\/faq\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"In StViewer, GigE Vision camera is displayed but the OK button cannot be selected, so I cannot use the camera.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sentech.co.jp\/en#website\",\"url\":\"https:\/\/sentech.co.jp\/en\",\"name\":\"\u30aa\u30e0\u30ed\u30f3\u30bb\u30f3\u30c6\u30c3\u30af\u682a\u5f0f\u4f1a\u793e\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/sentech.co.jp\/en#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sentech.co.jp\/en?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/sentech.co.jp\/en#organization\",\"name\":\"\u30aa\u30e0\u30ed\u30f3\u30bb\u30f3\u30c6\u30c3\u30af\u682a\u5f0f\u4f1a\u793e\",\"url\":\"https:\/\/sentech.co.jp\/en\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/sentech.co.jp\/en#\/schema\/logo\/image\/\",\"url\":\"https:\/\/sentech.co.jp\/wp-content\/uploads\/2025\/09\/ogp.png\",\"contentUrl\":\"https:\/\/sentech.co.jp\/wp-content\/uploads\/2025\/09\/ogp.png\",\"width\":1200,\"height\":630,\"caption\":\"\u30aa\u30e0\u30ed\u30f3\u30bb\u30f3\u30c6\u30c3\u30af\u682a\u5f0f\u4f1a\u793e\"},\"image\":{\"@id\":\"https:\/\/sentech.co.jp\/en#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"In StViewer, GigE Vision camera is displayed but the OK button cannot be selected, so I cannot use the camera. | FAQ | OMRON SENTECH CO., LTD.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sentech.co.jp\/en\/faq\/faq-7765","og_locale":"en_US","og_type":"article","og_title":"In StViewer, GigE Vision camera is displayed but the OK button cannot be selected, so I cannot use the camera. | FAQ | OMRON SENTECH CO., LTD.","og_description":"This occurs when the PC\u2019s network card (NIC) and the GigE Vision camera are not on the same network. Please check and adjust the IP address settings of both the NIC and the camera.The NIC\u2019s IP address can be checked in the Device Selection screen under Interface Information.The camera\u2019s IP address can be checked in [&hellip;]","og_url":"https:\/\/sentech.co.jp\/en\/faq\/faq-7765","og_site_name":"OMRON SENTECH CO., LTD.","article_modified_time":"2025-09-27T09:37:26+00:00","og_image":[{"width":1200,"height":630,"url":"https:\/\/sentech.co.jp\/wp-content\/uploads\/2025\/09\/ogp.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/sentech.co.jp\/en\/faq\/faq-7765","url":"https:\/\/sentech.co.jp\/en\/faq\/faq-7765","name":"In StViewer, GigE Vision camera is displayed but the OK button cannot be selected, so I cannot use the camera. | \u3088\u304f\u3042\u308b\u3054\u8cea\u554f | OMRON SENTECH CO., LTD.","isPartOf":{"@id":"https:\/\/sentech.co.jp\/en#website"},"datePublished":"2025-09-04T05:44:49+00:00","dateModified":"2025-09-27T09:37:26+00:00","breadcrumb":{"@id":"https:\/\/sentech.co.jp\/en\/faq\/faq-7765#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sentech.co.jp\/en\/faq\/faq-7765"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/sentech.co.jp\/en\/faq\/faq-7765#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u30db\u30fc\u30e0","item":"https:\/\/sentech.co.jp\/en"},{"@type":"ListItem","position":2,"name":"\u3088\u304f\u3042\u308b\u8cea\u554f","item":"https:\/\/sentech.co.jp\/en\/faq"},{"@type":"ListItem","position":3,"name":"In StViewer, GigE Vision camera is displayed but the OK button cannot be selected, so I cannot use the camera."}]},{"@type":"WebSite","@id":"https:\/\/sentech.co.jp\/en#website","url":"https:\/\/sentech.co.jp\/en","name":"\u30aa\u30e0\u30ed\u30f3\u30bb\u30f3\u30c6\u30c3\u30af\u682a\u5f0f\u4f1a\u793e","description":"","publisher":{"@id":"https:\/\/sentech.co.jp\/en#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sentech.co.jp\/en?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/sentech.co.jp\/en#organization","name":"\u30aa\u30e0\u30ed\u30f3\u30bb\u30f3\u30c6\u30c3\u30af\u682a\u5f0f\u4f1a\u793e","url":"https:\/\/sentech.co.jp\/en","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/sentech.co.jp\/en#\/schema\/logo\/image\/","url":"https:\/\/sentech.co.jp\/wp-content\/uploads\/2025\/09\/ogp.png","contentUrl":"https:\/\/sentech.co.jp\/wp-content\/uploads\/2025\/09\/ogp.png","width":1200,"height":630,"caption":"\u30aa\u30e0\u30ed\u30f3\u30bb\u30f3\u30c6\u30c3\u30af\u682a\u5f0f\u4f1a\u793e"},"image":{"@id":"https:\/\/sentech.co.jp\/en#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/sentech.co.jp\/en\/wp-json\/wp\/v2\/faq\/11708","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sentech.co.jp\/en\/wp-json\/wp\/v2\/faq"}],"about":[{"href":"https:\/\/sentech.co.jp\/en\/wp-json\/wp\/v2\/types\/faq"}],"wp:attachment":[{"href":"https:\/\/sentech.co.jp\/en\/wp-json\/wp\/v2\/media?parent=11708"}],"wp:term":[{"taxonomy":"faq_cate","embeddable":true,"href":"https:\/\/sentech.co.jp\/en\/wp-json\/wp\/v2\/faq_cate?post=11708"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}