FAQ

Camera settings

Is there any affect for camera performance when connecting multiple GigE Vision cameras?
Updated:
Tag:

While connecting multiple GigE Vision camera with Gigabit Ethernet supported switch, there are some affects including reduce frame rate and camera could not recognize when total amount of trasmitt data from GigE Vision cameras becomes more than 1Gbps.

Please reduce total amount of trasmitt data with reduce frame rata when connecting multiple GigE Vision camera with one Gigabit Ethernet supported switch.

How can I go back to factory default settings (initial settings) of camera?
Updated:
Tag:

USB3 Vision, GigE Vision and CoaXPress cameras have settings save and load functions.
There are two types of data can be saving onto camera.
Default: Unchangeable Factory default settings
UserSet: Changeable default settings
When loading “Default” data on camera, camera settings go back to factory default settings.
(USB2.0, USB3.0, Camera Link and Opt-C:Link cameras do not have factory default settings on camera.It is necessary to create “Default” settings file before change settings.)

Below is procedure to go back to factory default settings by StViewer.
1. Selects “Default” at “UserSetSelector” under “UserSetControl” on “RemoteDevice” after stop image acquisition.
2. When selecting “Execute” button at “UserSetLoad”, factory default settings are loads from camera.
3. To save factory default settings onto camera, selects “UserSet1” at “UserSetSelector” under “UserSetControl” on “RemoteDevice” then seleccts “Execute” button at “UserSetSave”.

When selecting “Default” at “UserSetDefault” under “UserSetControl” on “RemoteDevice”, power on camera with factory default settings.
When selecting “UserSet1” at “UserSetDefault” under “UserSetControl” on “RemoteDevice”, power on camera with saved UserSet1 settings.

The greenish image is acquired with USB/GigE Vision camera.
Updated:
Tag:

USB/GigE Vision cameras use Bayer CMOS image sensor.
The greenish image is acquired when selecting “OFF” at white balance or white balance settings are not appropriate.

Please adjusts white balance by following procedure:
The following is white balance adjustment procedure with StViewer (for USB3 Vision and GigE Vision)
1. Selects “Once” or “Continuous” at “Balance White Auto” under “AnalogControl” under “RemoteDevice” after stop image acquisition.
“Once”: White balance adjust automatically once
“Continuous”: White balance adjust continuously

The following is white balance adjustment procedure with StCamSWare (for USB3.0 and USB2.0)
1. Selects “Setting” under “Option” in menu of StCamSWare, then selects “Advanced” button on setting window.
2. Selects “WhiteBalance” Tab then selects one of “Manual”, “FullAuto” and “OneShot”.
“Manual”: White balance adjust manually
“FullAuto”: Whita balance adjust continuously
“OneShot”: White balance adjust automatically once

If “Default” UseSet loads, does IP address of camera also change?
Updated:
Tag:

IP address of camera does not change because IP address does not save into UserSet.
When changing IP address of camera, changed IP address save into memory on camera automatically.

The image becomes dark when reducing image resolution.
Updated:
Tag:

When selecting “Off” at “Exposure Mode” under “Acquisition Control” under “Remote Device”, expousre time that is keep maximum frame rate, set automatically.
The frame rate becomes high (fast) when reducing image resolution, and one frame period of time becomes shorten.
Then shorten exposure time makes dark image.

To fixed exposure time, selects “Timed” at “Exposure Mode” under “Acquisition Control” under “Remote Device” after fixed exposure time with this method, brightness of image is consistent and control by “Exposure Time” while reducing image resolution.