Please referes OpenCV sample code when acquired image by Sentech SDK, use with OpenCV.
The acquired image by Sentech SDK, copy to buffer for OpenCV then color conversion or display image with OpenCV functions.
Please refers “AutoFunctions” sample program for change camera setting.
Please refers sample code that displaying at bottom part of “NodeMap” when selecting function on StViewer for camera parameters.
Sentech SDK includes “Sentech GigE Vision filter driver” for our GigE Vision cameras.
This filter driver does not work with GigE Vision cameras from other camera manufacture.
Sentech SDK also includes device driver for our USB3 Vision cameras.
Please refer “Grab” or “GrabCallback” sample program for image acquisition.
These sample programs are acquring 100 images after connecting camera,
Grab is acquring images with roop process,
GrabCallback is acquring images with callback function.
Please refers “AutoFunction” sample program for camrea setting.
Please refer “GigEConfiguration” or “CameraSideROI” sample program for connecting and change camera settings for GigE Vision camera.
Please refers “SaveAndLoadImage” sample program for image data format conversion.
Please refer “SingleFilter” or “MultipleFilter” sample program for some image processing.
Please refers “SingleFilter” sample program for edge enhancement (sharpness) process.
Both “Grab” and “GrabCallback” sample programs are explain how to connect and acquire image.
The difference is:
“Grab” is acquiring image by roop processing on main thread.
“GrabCallback” is acquiring image with different thread by callback function.
The image data from Bayer CMOS image sensor color camera is before color conversion.
The size of image from color camera and monochrome camera is same.
It is possible to convert to color image data by using color conversion filter that is included in Sentech SDK.
Please refers “SaveAndLoadImage” sample program for how to use color conversion filter.
Sentech SDK (.NET) is .NET Framework2.0 based software package.
When Sentech SDK (.NET) using with .NET Framework 4.0 or later, it is necessary to replace automatically generated “app.config” file.
Please replace it by .NET Framework 4.0 supported “app.config” file that is included in sample programs of Sentech SDK (.NET).
The dll files of Sentech SDK is copied as below folder if installation folder did not change while Sentech SDK installation:
C:\Program Files\Common Files\OMRON_SENTECH
The following types of camera prameter are available:
IBoolean: True or False select parameter
IInteger: Integer value save parameter
IFloat: Float value save parameter
IEnumeration: Selection select parameter
IString: Character save parameter
ICommand: Command for camera execute parameter
The parameter control method is different based on type of camera parameter.
Please refers “AutoFunction” or “FeatureList” sample programs for parameter control method.
Please refers sample code that displaying at bottom part of “NodeMap” when selecting function on StViewer for camera parameters.